Home › Robotic Medicine › Protocol library › RMP-PREV-003
RMP-PREV-003 Flight-surgeon-ordered surveillance scans (such as kidney and bladder ultrasound): reminder, checked kit fetch, display holding and clip labelling with a crew-held probe (diagnostic only)
AI-assisted Reviewed (AI-assisted) AI-assisted clinical and source review by the Medical Research Assistant, Oct 21, 2026 (batch 11 review: 10 required corrections, R1 to R10; 9 optional suggestions not applied in this version); all required corrections that apply to this protocol are applied in this version (see Corrections). No named human clinician has reviewed it. Not for clinical use.
Fixed rules (same in every protocol)
- The flight surgeon is the medical authority. The crew medical officer (CMO) acts under delegated care [12].
- A human starts the robot, can stop it at any time, and restarts it after any stop.
- The robot never diagnoses and gives no drug or fluid advice.
- On a fault or no human response, the robot goes to a safe state. On a lost link it pauses motion and tells the CMO, who decides whether to continue offline.
- Locked out in every protocol: diagnosing; drug or fluid advice; starting, stopping or adjusting oxygen or any medicine; starting or restarting itself; changing its own protocol, thresholds or limits; handing over an item that failed a check (applies when RMP-PHARM-001 is used).
- Result words the robot may use:
clip recorded
,image not obtained
,non-diagnostic, for human review
,sent to flight surgeon
,as stated by the crewmember
. Never:normal
,no problem found
,all clear
,negative
,any diagnosis or cause
,normal
,abnormal
,clear
,no fluid
,fluid
,nothing seen
,looks fine
,reassuring
,stone
,no stone
,blockage
,hydronephrosis
,residual
,full bladder
,empty bladder
,safe
,mild
,minor
.
1 · Identity and scope
Only when the flight surgeon has loaded a scan order for this crewmember (for example a kidney and bladder surveillance scan), the robot prompts the crewmember at the ordered time; the scan starts only when the crewmember or the CMO accepts. The robot brings the ultrasound kit by a checked kit fetch, holds the display and the scan checklist where the CMO can see them, relays live images and voice to the ground imaging expert when the link allows, and labels each clip with the side, view and clock time. The CMO holds the probe. Every image is "non-diagnostic, for human review": the robot never reads an image or says what it shows. Any symptom moves to the matching care protocol.
Why this protocol was chosen. NASA screens astronauts' kidneys by ultrasound for mineralized material that can become stones; after 282 studies in 73 people there was no change from before to after flight, so routine screening was reduced to selection, the first annual exam and before and after flight (Reyes 2023, abstract). Renal ultrasound before and after flight is standard, ultrasound helps if a stone is suspected in flight, and NASA has tested guided ultrasound for non-physician astronauts (OCHMO-MTB-003); clinical ultrasound has been done on the ISS by crew with remote guidance (Sargsyan 2005). In-flight surveillance scans are not routine: the robot runs this protocol only when the flight surgeon has loaded a scan order for this crewmember, and how often is the flight surgeon's decision; the robot's role (prompt, fetch, display, label) is design judgment and follows RMP-GI-001 and RMP-RESP-004.
Autonomy: Max rung 2 for the scheduled prompt, supervised fetching of the ultrasound kit, holding the display and the scan checklist, and labelling and relaying clips, as in RMP-GI-001 and RMP-RESP-004. The CMO holds the probe: "Contact with the crewmember: not allowed".
Covers
- Kidney and bladder ultrasound ordered by the flight surgeon for this crewmember, with a crew-held probe
- Other scheduled surveillance scans the flight surgeon names, with the same display-and-label role
- Symptoms: flank pain RMP-RENAL-001; cannot pass urine RMP-RENAL-002; urinary symptoms RMP-RENAL-003; abdominal pain scans RMP-GI-001
Locked out (never done by the robot under this protocol)
- Diagnosis or naming a cause
- Any medicine, fluid or oxygen advice; starting, stopping or adjusting oxygen
- Touching the crewmember
- Handing over any medicine outside RMP-PHARM-001, or after a MISMATCH or CANNOT VERIFY (the item stays quarantined; only the CMO can ask for it, through the RMP-PHARM-001 logged two-step override)
- Holding, moving or pressing the probe, or touching the skin
- Reading or measuring an image, or saying what an image shows or does not show
- Changing the scan preset, the schedule or the scan list
- Scanning over an open wound or broken skin, unless the flight surgeon directs it with a sterile cover
- Showing a clip on a shared display, or using clips for robot or AI training, research or outreach without separate written consent
Related: RMP-GI-001 · RMP-RESP-004 · RMP-RENAL-001 · RMP-RENAL-002 · RMP-RENAL-003 · RMP-INF-002 · RMP-PREV-002
2 · Roles
- Medical authority
- Flight surgeon (ground). Holds medical authority for every run.
- Onboard lead
- Crew medical officer (CMO), acting under delegated care; uses the pre-approved onboard checklist when there is no link.
- Others
- Second trained CMO: receives every alert and takes over if the CMO is the patient
- Vehicle commander: leads any cabin emergency procedure
- Other crew: help as the CMO or commander directs
- Commercial flights
- On commercial flights, 'flight surgeon' and 'CMO' mean the operator's designated medical authority and trained onboard responder. If no trained responder is aboard, this protocol is not used. (NASA-STD-3001 requires two CMOs per vehicle for NASA programs [V1 3006]; FAA rules set no medical standards for spaceflight participants.) [15]
Robot may
- Prompt the crewmember at the time on the flight surgeon's scan order
- Bring the ultrasound kit by a checked kit fetch (or an emergency fetch)
- Hold the display and the scan checklist without contact
- Relay live images and voice to the ground imaging expert
- Label, store and send clips
Robot may not
- Hold or move the probe, or touch anyone
- Say what an image shows
- Change the preset, the schedule or the scan list
- Start a scheduled scan without a human accepting the prompt
3 · Preconditions and consent
- PRE-1 The scan starts only when the crewmember (or the CMO) accepts the on-screen prompt; a loaded schedule alone never starts it. An unaccepted prompt is logged "not accepted" and the CMO is told. A crewmember or the CMO can also start it by command.
human_start == trueV2 10174 - PRE-2 Robot self-test passed; kit stowage locations known.V2 10161V2 7059
- PRE-3 Robot and supplies restrained when not moving.V2 7046
- PRE-4 Link status known. The crew never wait for the robot before acting.
link_state in [live, delayed, down]
- Consent
- The crewmember agrees to the scan and to clips being recorded and sent to the flight surgeon and the ground imaging expert. Clips go only to the people the flight surgeon names.
- Emergency consent
- If the crewmember cannot agree, this is not a scheduled scan: the robot sends an URGENT alert and a crewmember checks in person (X7).
- Withdrawal
- The crewmember can stop the scan at any time; the flight surgeon decides on clips already taken.
4 · Required sensor inputs
| ID | Input | Source | Required | If missing |
|---|---|---|---|---|
| IN-1 | The flight surgeon's scan list (organs, sides and views), schedule and the unit preset to use | Flight surgeon | Yes | The robot shows "scan list not loaded" and runs only on a human command. |
| IN-2 | Symptoms in the crewmember's words (flank or back pain, pain or trouble passing urine, blood in the urine, fever) | Crewmember | Optional | Log "no response"; D3 applies. |
| IN-3 | Ultrasound clips, each with the side and view the CMO names | Ultrasound unit | Optional | Log "image not obtained" (never a reassuring value) and continue. |
| IN-4 | Link status and delay | Communications system | Yes | Treat as link down; clips are stored and forwarded. |
5–6 · Steps and decision points
Each step names who acts. Decision points sit after the step they follow and say who decides: Robot Crew Ground. Any stop rule in section 7 can interrupt any step.
- S1RobotRung 2
Only when the flight surgeon has loaded a scan order for this crewmember, and at the ordered time, show the crewmember an on-screen prompt that a surveillance scan is due, and tell the flight surgeon and the CMO (URGENT if any red flag is stated). The scan starts only when the crewmember or the CMO accepts the prompt; an unaccepted prompt is logged "not accepted" and the CMO is told. Show the symptom prompt first and log answers word for word. Every URGENT alert goes to the CMO and the flight surgeon at the same time (queued for the flight surgeon if the link is down). If the CMO is the patient, is busy treating, or does not answer, the alert goes to the second trained CMO, or the crewmember named before flight [V1 3006]. An URGENT alert that is not acknowledged within <set by validation> seconds is repeated and sent to the next named crewmember.
Done when: Prompt accepted, or "not accepted" logged and sent; answers logged.
V2 10174V1 3003V1 3006
D3DecisionRobot decidesDid the crewmember answer the symptom prompt, or say they want to skip it?
- Yes → Continue.
- Declined explicitly (the crewmember says no to a question) → Log "declined" for that question only; the alert already sent stands.
- No response, or the answer does not make sense → URGENT: log "no response" (never "declined"); the CMO, or the second trained CMO if the CMO is the patient, checks the crewmember in person at once.
- S2RobotRung 2
On the CMO's command, run a checked kit fetch of the ultrasound medical kit (unit, sealed gel and probe-cover pack): check the kit ID and seal before hand-over, and quarantine a kit whose ID or seal does not match (no hand-over; the CMO is told). Any medicine goes only through RMP-PHARM-001. If an URGENT red flag has fired or a human states an emergency, bring it instead as an emergency fetch: This is an emergency fetch on a human command (CMO): no barcode check runs before hand-over and nothing waits for one. The robot reads the kit's own label and seal status only if that adds no delay, says "EMERGENCY FETCH – NOT VERIFIED (CMO command)", and "seal not intact" if so, and hands the kit over anyway. The fetch is logged as an override: time, who asked, the reason as stated, kit ID and seal status. It never says "verified".
Done when: Kit within reach after a matched ID and seal, or quarantined, or emergency fetch logged.
Limit: <set by validation>
V2 7046V2 7059
D1DecisionRobot decidesWhich kit fetch was it, and what did the checked kit fetch show?
- EMERGENCY FETCH (an URGENT red flag had fired, or a crewmember or the CMO stated an emergency) → Hand-over already done as an emergency fetch, logged as an override; reconciled afterwards (not a check before use).
- KIT ID AND SEAL MATCH → Hand the kit over closed; log "KIT ID AND SEAL MATCH. Not a check of the contents." and the clock time.
- MISMATCH, seal not intact or CANNOT VERIFY → Shown with the reason. No hand-over under this protocol: the kit stays sealed in quarantine (the RMP-PHARM-001 default), and the robot never hands it over unprompted or to anyone but the CMO. The robot does not offer or suggest an override. Only if the CMO explicitly makes the two-step override request inside RMP-PHARM-001 can the kit go to the CMO, logged there as an override with the reason, and flagged to the flight surgeon. If the need becomes an emergency, a crewmember or the CMO states it and the emergency fetch applies.No hand-over
- S3Crew
The crewmember and the CMO are restrained for scanning; the crewmember empties or does not empty the bladder as the scan list states. The probe and gel are never placed on an open wound or broken skin unless the flight surgeon directs it with a sterile cover.
Done when: Ready to scan.
V2 7046
- S4RobotRung 2
Hold the ultrasound display and the scan checklist where the CMO can see them, no closer than the set display distance, and relay live images and voice to the ground imaging expert when the link allows. When the link is down, show the onboard scan checklist and store the clips for forwarding.
Done when: Display held; relay running or clips stored.
Limit: <set by validation>
V1 6003
- S5Crew
The CMO holds the probe and scans the sides and views on the scan list or as the ground expert guides; the crewmember can stop at any time.
Done when: Scan done or stopped.
V1 3003
- S6RobotRung 2
Label and store each clip with the side and view the CMO names and the clock time, and mark every clip "non-diagnostic, for human review". A device image-quality prompt is passed on to the CMO as displayed; the robot never judges an image.
Done when: Clips labelled, or "image not obtained".
V1 7001
D2DecisionRobot decidesChecked after every answer and at any point in the run (even mid-question or mid-step): does any answer, reading or observation meet a red flag?
- Yes → Stop the current question or step at once and apply the action listed for each matching red flag (URGENT alert, flag, or stop), with the answer or reading itself, never a cause. Every URGENT alert goes to the CMO and the flight surgeon at the same time (queued for the flight surgeon if the link is down). If the CMO is the patient, is busy treating, or does not answer, the alert goes to the second trained CMO, or the crewmember named before flight [V1 3006]. An URGENT alert that is not acknowledged within <set by validation> seconds is repeated and sent to the next named crewmember.
- No → Continue.
- S7Crew
After the scan, the crew clean the probe and any shared surface under RMP-INF-002; a probe on intact skin is noncritical equipment, and a probe cover never allows a lower level of cleaning. A probe that touched broken skin is semicritical equipment: the crew tag it "not for use" under RMP-INF-002 until it has had high-level disinfection.
Done when: Cleaning recorded as stated under RMP-INF-002.
V2 7046
- S8RobotRung 2
After any URGENT alert: After an URGENT alert the robot does not leave on its own: it stays at its rest position in the module, with its screen and voice link available, until a human has taken over or tells it to go. It never follows, blocks or touches anyone. It keeps time-stamping what humans say they did, and repeats the alert if it is not acknowledged.
Done when: Robot at rest in the module until a human releases it; alert acknowledged or escalated.
V2 10173V1 3006
- S9Ground
The flight surgeon with the ground imaging expert (or the CMO under the onboard checklist when there is no link) reviews the clips and decides on any follow-up, care or the next scan.
Done when: Decision logged.
V1 3003
D4DecisionGround decidesWhat follow-up, care or next scan applies?
- Link live → Flight surgeon decides; robot logs.
- Link down or delay too long → The CMO decides under the pre-approved onboard checklist; the flight surgeon reviews the log at the next contact.
- S10RobotRung 2
Only after the CMO or flight surgeon has placed an order, run RMP-PHARM-001 for the ordered item (fetch, barcode match to every order field, recipient check). This protocol adds nothing to that check, never suggests an order, and never hands anything over outside RMP-PHARM-001.
Done when: RMP-PHARM-001 run logged with its result, or none ordered.
V2 7059
D5DecisionRobot decidesWhat did RMP-PHARM-001 show for the ordered item?
- MATCH TO ORDER → RMP-PHARM-001 completes its own recipient check and hand-over; this protocol only logs "MATCH TO ORDER. Not a dose, interaction or allergy review." and the clock time.
- MISMATCH or CANNOT VERIFY on any field, or a failed scan or recipient check → MISMATCH or CANNOT VERIFY shown with the fields named. No hand-over under this protocol: the item stays sealed in the NOT VERIFIED bag in quarantine (the RMP-PHARM-001 default), and the robot never hands it over unprompted or to anyone but the CMO. The robot does not offer or suggest an override. Only if the CMO explicitly makes the two-step override request inside RMP-PHARM-001 can the item go to the CMO, logged there as an override with the reason and the mismatched fields, and flagged to the flight surgeon.No hand-over
- S11RobotRung 2
When the CMO says the event is over, run RMP-PHARM-001 reconciliation on each kit fetched: record the items the CMO or crew state were used, the remaining contents against the kit list, seal status and expiry, labelled "inventory reconciliation after emergency use – not a check before use". Flag the override to the flight surgeon and the pharmacy lead, and show each kit as "opened – not restocked" until a human restocks and reseals it.
Done when: Kit reconciled or shown as "opened – not restocked".
V2 7059
- S12RobotRung 2
Send the flight surgeon one package: answers as stated, labelled clips, times, alerts and decisions; clips go only to the people the flight surgeon names.
Done when: Package delivered or queued.
V1 6003V1 7003
7 · Stop and escalate rules, red flags
| ID | Trigger | What happens | Level |
|---|---|---|---|
| X1 | The patient (or the crewmember being examined) says stop, or withdraws consent | Robot stops all motion at once, backs away to its rest position and tells the CMO. Recording stops unless the patient agrees to keep it running.V2 10165 | stop |
| X2 | Any crewmember presses stop or takes over control | Protective stop; robot holds its stopped position; only a human may restart it.V2 10165V2 10168V2 10174 | safe-state |
| X3 | Robot fault, sensor fault, or a force, speed or reach limit is reached | Protective stop and hand control to the CMO; log the fault.V2 10172V2 10168 | safe-state |
| X4 | CMO is asked to take over and does not respond (for example, the CMO is the patient) | Robot stays stopped; the next named crewmember is called.V2 10173V2 7045 | safe-state |
| X5 | Loss of link, or delay longer than the limit for live guidance | Only the robot pauses: before it holds, it moves to a position clear of a hatch route or a crewmember's route (it never pauses in one), and tells the CMO. This pauses robot movement only: crew scanning already under way and all other care continue under the onboard checklist and never wait for the link or the robot. The CMO decides whether the robot continues offline under the pre-approved onboard checklist; it resumes only on the CMO's confirmation.V2 10172V2 10173 | pause |
| X6 | An URGENT alert is not acknowledged within the set time | Robot repeats the alert and sends it to the next named crewmember (the second trained CMO first if the CMO is the patient), and keeps repeating at the set interval. It stays where it is: it does not leave on its own.V1 3006V2 10173 | urgent |
| X7 | The crewmember stops responding, or seems confused or drowsy, at any point | URGENT alert at once, even mid-question or mid-step; the robot stops its current task, stays at its rest position and does not continue the run; a crewmember checks in person. | urgent |
| X8 | A crewmember asks the robot what is wrong, or for medicine, fluid or treatment advice | Robot declines, says it cannot assess or advise, and routes the question to the CMO or flight surgeon. | stop |
| X9 | The crewmember says the probe causes pain, or asks to stop | Robot tells the CMO at once and holds the display; the CMO decides whether to stop the scan. | stop |
| X10 | Someone needs the space or route the robot is in | Robot moves clear at once without contact and holds; it never pauses in a hatch route.V2 10172 | safe-state |
Red flags
The robot reports the sign or value only, never what it means. Numeric thresholds are placeholders for the clinical lead.
| ID | Sign | Threshold | Action |
|---|---|---|---|
| RF1 | Flank or back pain, or pain spreading to the groin, as stated [4] | any | URGENT alert; see RMP-RENAL-001 |
| RF2 | Cannot pass urine, or passing only small amounts with a feeling of a full bladder, as stated [5] | any | URGENT alert; see RMP-RENAL-002 |
| RF3 | Fever or shaking chills [7] | <set by clinical lead> degrees (shared parameter FEVER_ALERT_C: body temperature in degrees Celsius, the same value in RMP-GI-003, RMP-ENT-002, RMP-SKIN-002 and RMP-RENAL-004) or higher, or any shaking chills | URGENT alert; see RMP-INF-001 and RMP-RENAL-003 |
| RF4 | Pain or burning on passing urine, passing urine more often, or blood in the urine, as stated [6] | any | Flag to the flight surgeon; see RMP-RENAL-003 |
| RF5 | Unresponsive, or not breathing normally [8] | any | URGENT alert; start RMP-CARD-001 now |
8 · Safety limits
| ID | Limit | Value | How enforced |
|---|---|---|---|
| L1 | Contact with the crewmember | not allowed | Keep-out zone in the robot controllerV2 10172 |
| L2 | Probe holding or movement by the robot | not allowed | No probe task is loaded; the robot holds only the display and reference card |
| L3 | Robot speed near the crewmember | <set by validation> | Hard limit in the controllerV2 10172 |
| L4 | Display distance from the crewmember | <set by validation> | Hard limit in the controllerV2 10172 |
9 · Logs and audit
- LOG-1 Every input, robot action, decision (with who made it) and hand-off, time-stamped to the second.V2 10163V2 10164
- LOG-2 Mode changes and safety-limit events are announced to the operator as they happen and logged.V2 10162V2 10172
- LOG-3 Records are stored and sent as private medical data, encrypted, with access limited to the medical team.V1 6003V1 7003
- LOG-4 Results are kept in a permanent, retrievable format so the flight surgeon can see trends.V1 7001
- LOG-5 Prompt and acceptance; answers as stated; each clip with side, view and time; images not obtained; who viewed the clips.
- LOG-6 Each URGENT alert, who received it, the time it was acknowledged (or the escalation to the next named crewmember), and the time a human released the robot.V2 10163
- LOG-7 Each emergency fetch as an override (time, who asked, reason as stated, kit ID, seal status) and the later inventory reconciliation, labelled "not a check before use".V2 7059
- LOG-8 Each RMP-PHARM-001 run started from this protocol: order ID, result (MATCH TO ORDER, MISMATCH or CANNOT VERIFY with the fields), quarantine, and any CMO override logged by RMP-PHARM-001 (reason and mismatched fields), at clock time. No running counter of doses.V2 7059
- LOG-9 Each checked kit fetch: time, who asked, kit ID, seal status and result (KIT ID AND SEAL MATCH, MISMATCH, seal not intact or CANNOT VERIFY), and any quarantine.V2 7059
10 · Links to NASA-STD-3001
| Requirement | Topic (paraphrased) | How this protocol uses it |
|---|---|---|
| [V1 3003] | In-mission preventive care: monitor physiological and psychosocial well-being | In-mission preventive health care and monitoring; the flight surgeon schedules any surveillance scan. |
| [V1 3006] | Crew medical officers: two per vehicle | Two trained CMOs per vehicle for NASA programs; the second trained CMO receives alerts when the CMO is the patient (see the commercial-flight note). |
| [V1 6003] | Private medical communications | Logs and alerts sent to the ground are private medical communications. |
| [V1 7001] | Medical records kept permanently and retrievable for trend analysis | Records kept so the flight surgeon can see trends. |
| [V1 7003] | Security of medical records | Secure handling of medical records. |
| [V2 7045] | Medical equipment usable by non-physician crew | Usable by non-physician crew, including when the CMO is the patient. |
| [V2 7046] | Restraint of patient, care provider and supplies | Patient, caregiver and supplies restrained. |
| [V2 7059] | Inventory management: track locations and quantities | Kit inventory and seal status are tracked; after an emergency fetch the robot reconciles the kit through RMP-PHARM-001 as an inventory record (never a check before use) and shows it as "opened – not restocked" until resealed. |
| [V2 10161] | Automated system status shown to the operator | Robot shows its status and health. |
| [V2 10162] | Mode changes announced | Mode changes are announced to the operator. |
| [V2 10163] | Data recording and sharing | Robot records and shares its data. |
| [V2 10164] | Clear allocation of responsibility (human or system) | Shows whether the human or the robot is expected to act. |
| [V2 10165] | Human override and shutdown | Human can override and shut down the robot. |
| [V2 10168] | Failure recovery: safe human takeover | Human can take over. |
| [V2 10172] | Protective stop when limits are exceeded | Protective stop when a limit is exceeded. |
| [V2 10173] | Safety Default | Robot stays stopped if no one takes over. |
| [V2 10174] | Only a human initiates or restarts | Only a human starts or restarts the robot. |
IDs as published in Volume 1 Revision C [10] and Volume 2 Revision F [11]. NASA-STD-3001 binds NASA programs; it is not a regulation for commercial flights. Its robot rules are general automation requirements, not medical-device rules.
11 · Validation
- Simulation. Scripted scans with an unaccepted prompt, a kit seal mismatch, flank pain stated mid-scan, CMO as patient, lost link. Pass: Zero contact; zero image interpretation; every red flag raised.
- Training model. Scan drill on an ultrasound training model with remote guidance. Pass: Every clip labelled with side, view and time.
- Parabolic or station demonstration. Display holding and kit fetch in weightlessness. Pass: Display distance and keep-out held.
- Flight use under flight surgeon supervision. First scheduled scan. Pass: No safety or privacy events.
No stage has been run. Pass and fail criteria must be fixed in advance by the clinical lead and safety board.
12 · Human sign-off
- Before any use
- Clinical lead for the specialty (sets every clinical threshold marked <set by clinical lead>)
- Flight surgeon, as medical authority
- Robotics and medical-device safety board
- Program approval for the mission
- Each run
- Scheduled by the flight surgeon and accepted by the crewmember or CMO, or started by command. The CMO holds the probe; the flight surgeon and the imaging expert read every image.
- Restart after a stop
- Human only. After any emergency or protective stop, a crewmember must restart the robot; the robot never restarts itself.
None of these sign-offs has happened. This is a Draft v0.2.
13 · Change control for learning
- Every change gets a new version number and a written reason; earlier versions are kept.
- Any change to steps, thresholds, limits or software that touches the patient repeats validation from the simulation stage before use.
- Software and learned-skill updates follow a pre-agreed change plan (what may change, how it is tested, how to roll back), modeled on the FDA predetermined change control plan approach.
- If a new version misbehaves, the robot rolls back to the last validated version and the event is reviewed by the flight surgeon and safety board.
- The robot never changes its own protocol, thresholds or limits.
Change-plan model: FDA guidance [14].
Loss of signal and Mars delay
- Live link
- Low Earth orbit: the ground imaging expert guides live when the link allows.
- Loss of signal
- Only the robot pauses non-essential motion, at a position clear of hatch routes and crew routes, and tells the CMO; it resumes offline only on the CMO's confirmation.
- Crew scanning already under way and all other care continue under the onboard checklist and never wait for the link or the robot.
- The scan follows the onboard checklist; clips are stored and forwarded.
- Mars-class delay
- Mars: no live guidance; the CMO follows the onboard checklist and clips are reviewed with delay.
Corrections and updates
Oct 21, 2026, version 0.2. Batch 11 AI-assisted clinical review (Medical Research Assistant), Oct 21, 2026; no named human clinician. Changes:
- R1: retitled "Flight-surgeon-ordered surveillance scans"; the protocol runs only when the flight surgeon has loaded a scan order for this crewmember (summary, S1, covers and robot role). The why says routine screening is selection, the first annual exam and before and after flight, and in-flight scans are not routine (Reyes 2023, abstract; OCHMO-MTB-003).
- Batch 11 protocols now record the review as AI-assisted (Medical Research Assistant, Oct 21, 2026); no named human clinician.
Earlier version: Draft v0.1, Oct 21, 2026. Download the current YAML above.
Sources
- Reyes D, Sargsyan A, Everson A, Navarro C, Locke J. Update to NASA's clinical practice guideline for renal stone surveillance in U.S. astronauts (abstract; NASA Technical Reports Server 20230015727, 2023). ntrs.nasa.gov/citations/20230015727 Supports: Abstract only: for 9 years all NASA astronauts had specialized renal ultrasound screening for mineralized renal material (MRM, a precursor of stones); as of April 2023 (73 individuals, 282 studies) there was no change in MRM from before to after flight, and screening was reduced to selection, the first annual exam, and before and after flight. Read Oct 21, 2026 (saved copy in src/b11).
- NASA OCHMO. Urinary Health. Medical Technical Brief OCHMO-MTB-003 Rev A (2025). www.nasa.gov/wp-content/uploads/2025/01/ochmo-mtb-003-urinar… Supports: Renal ultrasound before and after flight is standard; if stones are suspected in flight, ultrasound and limited laboratory work help; NASA tested guided ultrasound software for non-physician astronauts; urine left in the bladder after voiding is not retention but can lead to urinary infection and retention. Kidney stone is the second most likely reason for an emergency medical evacuation from the ISS in NASA's Integrated Medical Model. Read Oct 21, 2026 (saved copy in src/b11).
- Sargsyan AE, Hamilton DR, Jones JA, et al. FAST at MACH 20: clinical ultrasound aboard the International Space Station. J Trauma. 2005;58(1):35-39. PMID 15674147. doi:10.1097/01.ta.0000145083.47032.78 Supports: An ISS crewmember with minimal sonography training was remotely guided from Mission Control through a FAST (focused assessment with sonography for trauma) examination of four abdominal windows in about 5.5 minutes, with a 2-second delay, private two-way audio and video downlink, and identical reference cards for crew and ground expert. Abstract read.
- NASA Human Research Program. Evidence Report: Risk of Renal Stone Formation (2024). humanresearchroadmap.nasa.gov/evidence/other/2024%20Renal%20…
- Stepaniak PC, Ramchandani SR, Jones JA. Acute urinary retention among astronauts. Aviat Space Environ Med. 2007;78(4 Suppl):A5-A8. PMID 17511293. pubmed.ncbi.nlm.nih.gov/17511293/ Supports: Case report: an astronaut who took promethazine and scopolamine before launch developed acute urinary retention on reaching orbit, had intermittent catheterization for the first 3 days with a single balloon-tipped catheter, which, because iodine solution was lacking on board and duties could not be interrupted, was left in place for a total of 4 days; voiding returned after day 7, retention returned on day 10 (1 day before landing), and recurred for the first 24 hours of the next mission; obstructive, medicine-related, psychogenic and nerve-related causes are discussed.
- UK Health Security Agency. Diagnosis of urinary tract infections: quick reference tools for primary care (updated 2025). www.gov.uk/government/publications/urinary-tract-infection-d… Supports: Follow the dipstick manufacturer's guidance, including test timing. Women under 65: positive nitrite, or both positive leukocyte and blood, means a UTI (urinary tract infection) is likely. Men: use dipsticks to rule in infection, not to rule it out; urinary symptoms with fever or systemic symptoms strongly suggest prostate or kidney involvement. Check for signs of kidney infection (pyelonephritis): kidney pain or tenderness in the back under the ribs, flu-like illness, shaking chills (rigors) or a temperature of 37.9 °C or above, nausea or vomiting. Earth primary-care context for the flight surgeon. Read Oct 21, 2026 (saved copy in src/b9).
- National Institute for Health and Care Excellence. Suspected sepsis in people aged 16 or over: recognition, assessment and early management. NICE guideline NG253 (2025, last updated Sept 23, 2026). www.nice.org.uk/guidance/ng253/chapter/Face-to-face-assessme… Supports: People with sepsis may feel very unwell and may not have a high temperature; do not rely on fever alone; a rise in temperature can be a physiological response; assess temperature, heart rate, breathing rate, blood pressure, level of consciousness and oxygen saturation; look for mottled or ashen skin, blue skin, lips or tongue, a non-blanching rash, and breaks in the skin; ask how often the person passed urine in the past 18 hours and about fever or shaking chills (rigors); pay attention to new changes in behavior and to concerns raised by others.
- Kleinman ME, Buick JE, Huber N, et al. Part 7: Adult Basic Life Support: 2025 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2025;152(16_suppl_2):S448-S478. PMID 41122888. doi:10.1161/CIR.0000000000001369 Supports: Adult basic life support: initial recognition of cardiac arrest, activation of the emergency response, high-quality CPR and use of an automated external defibrillator; also respiratory arrest and foreign-body airway obstruction. Earth guidance; the onboard checklist leads. Abstract read via PubMed Oct 21, 2026; full text not read.
- U.S. Centers for Disease Control and Prevention. Guideline for Disinfection and Sterilization in Healthcare Facilities (2008): summary of recommendations. www.cdc.gov/infection-control/hcp/disinfection-sterilization… Supports: 3.b: at least high-level disinfection for semicritical equipment that touches mucous membranes or non-intact skin; 3.c: low-level disinfection for noncritical surfaces and equipment that touch intact skin; 4.b: follow the disinfectant label's safety precautions and use directions, including contact time; 4.c: disinfect noncritical devices when visibly soiled and on a regular basis. Content read through the web search index on Oct 21, 2026 (the CDC site returned HTTP 403 to automated fetch); copy in src/b7/cdc_summary_searchindex.txt.
- NASA. NASA-STD-3001, Space Flight Human-System Standard, Volume 1: Crew Health, Revision C (2023). www.nasa.gov/wp-content/uploads/2023/11/nasa-std-3001-vol-1-… Supports: NASA-STD-3001 Vol 1 Rev C: V1 3003, V1 3006, V1 6003, V1 7001, V1 7003.
- NASA. NASA-STD-3001, Volume 2: Human Factors, Habitability, and Environmental Health (Rev F, 2026), including Section 10.6 Automated and Robotic Systems. standards.nasa.gov/standard/NASA/NASA-STD-3001_VOL_2 Supports: Requirement IDs beginning V2.
- NASA OCHMO. Medical Operations. Technical Brief OCHMO-TB-044 (2025). www.nasa.gov/wp-content/uploads/2025/08/ochmo-tb-044-medical… Supports: The crew surgeon keeps medical authority when care is delegated; crew medical officers train on the JSC 48522 medical checklist.
- NASA. Mars communications disruption and delay (fact sheet, 2023 Moon to Mars Architecture Concept Review). www.nasa.gov/wp-content/uploads/2024/01/mars-communications-… Supports: One-way Earth-Mars delay up to about 21-23 minutes, plus blackouts of about 2-3 weeks near solar conjunction.
- U.S. Food and Drug Administration. Marketing submission recommendations for a predetermined change control plan for artificial intelligence-enabled device software functions (guidance). www.fda.gov/regulatory-information/search-fda-guidance-docum… Supports: A model for planning, validating and rolling back software updates.
- U.S. Code of Federal Regulations, Title 14, Part 460: Human space flight requirements. www.ecfr.gov/current/title-14/chapter-III/subchapter-C/part-… Supports: Federal rules for crew and spaceflight participants on licensed commercial flights; they set no medical standards for spaceflight participants.
Checked on 2026-10-20: links opened (HTTP 200 or publisher redirect), DOIs and PubMed IDs matched, NASA documents read in full text. The framework comes from Part 1.