RMP-PREV-002 Periodic health exam support: reminder, checked kit fetch, vital signs as displayed, consented photos and a secure record (the CMO examines)
AI-assisted Reviewed (AI-assisted) AI-assisted clinical and source review by the Medical Research Assistant, Oct 21, 2026 (batch 10 review: 10 required corrections, R1 to R10, of which R10 applies to RMP-CARD-004, RMP-EGR-002, RMP-EGR-003 and RMP-NEURO-005; 20 optional suggestions); all required corrections that apply to this protocol are applied in this version (see Corrections). No named human clinician has reviewed it. Not for clinical use.
Fixed rules (same in every protocol)
- The flight surgeon is the medical authority. The crew medical officer (CMO) acts under delegated care [9].
- A human starts the robot, can stop it at any time, and restarts it after any stop.
- The robot never diagnoses and gives no drug or fluid advice.
- On a fault or no human response, the robot goes to a safe state. On a lost link it pauses motion and tells the CMO, who decides whether to continue offline.
- Locked out in every protocol: diagnosing; drug or fluid advice; starting, stopping or adjusting oxygen or any medicine; starting or restarting itself; changing its own protocol, thresholds or limits; handing over an item that failed a check (applies when RMP-PHARM-001 is used).
- Result words the robot may use:
reading as displayed
,reading not obtained
,finding as stated by the CMO
,photo recorded
,photo not obtained
,logged, not interpreted
,sent to flight surgeon
. Never:normal
,no problem found
,all clear
,negative
,any diagnosis or cause
,high
,low
,in range
,out of range
,healthy
,fit
,fit for duty
,good
,better
,worse
,stable
,unchanged
,reading is reassuring
,safe
,mild
,minor
.
1 · Identity and scope
At the times the flight surgeon schedules, the robot prompts the crewmember that a periodic health exam is due; the exam starts only when the crewmember (or the CMO) accepts. The robot brings the exam kit by a checked kit fetch, shows the flight surgeon's exam checklist and the RMP-CARD-005 preparation checklist for blood pressure, records vital signs as displayed and the CMO's findings word for word, takes consented photos of only the areas the checklist lists, and sends one secure package to the flight surgeon. A default checklist (design judgment) covers vital signs including temperature and body mass, a symptom review, skin, hands and feet, mouth and throat, eyes (imaging under RMP-EYE-003) and musculoskeletal complaints; the flight surgeon owns and changes it. Behavioral health stays in the private RMP-BEH-002 and RMP-BEH-003, never in this exam log.
Why this protocol was chosen. Programs must provide in-mission capabilities to monitor physiological and psychosocial well-being and deliver preventive health care (V1 3003), and medical records must be kept in a retrievable form for trends (V1 7001) and handled securely (V1 7003). Accurate blood pressure needs a standard technique, including no caffeine, exercise or smoking in the 30 minutes before, quiet rest, an arm supported at heart level and the right cuff size (Muntner 2019); RMP-CARD-005's checklist is reused. Photos follow the RMP-SKIN-003 rules (IMI 2019: standard views, an establishing view with surrounding skin, consent). What the exam covers, how often, and the alert values are set by the flight surgeon; the robot's role (prompt, fetch, checklist, record only) is design judgment. The shared value SPO2_ALERT_PCT only raises an alert; it never gates a crew action (the crew act without waiting for a reading), and the clinical lead sets it per mission with the flight surgeon, because the cabin atmosphere can differ by mission.
Autonomy: Max rung 2 for the scheduled prompt, a checked kit fetch, showing the flight surgeon's exam checklist, recording vital signs as displayed and the CMO's findings as stated, and consented photos of listed areas only. The crewmember or CMO places every device; the robot never touches anyone and never judges a finding.
Covers
- Periodic health exams on the flight surgeon's schedule, in flight or on a planetary surface
- Vital signs as displayed by crew-placed devices; the CMO's findings as stated; consented photos of listed areas
- Scheduled blood pressure checks alone: RMP-CARD-005; eye imaging: RMP-EYE-003; kit readiness: RMP-PREV-001
Locked out (never done by the robot under this protocol)
- Diagnosis or naming a cause
- Any medicine, fluid or oxygen advice; starting, stopping or adjusting oxygen
- Touching the crewmember
- Handing over any medicine outside RMP-PHARM-001, or after a MISMATCH or CANNOT VERIFY (the item stays quarantined; only the CMO can ask for it, through the RMP-PHARM-001 logged two-step override)
- Placing, inflating or removing any device, or touching anyone
- Saying whether a reading or finding is normal, high, low or changed, or that a crewmember is fit
- Changing the exam checklist, the schedule or the alert values
- Photographing any area not on the checklist, or any photo without consent
- Showing a photo or record on a shared display, or using them for robot or AI training, research or outreach without separate written consent
Related: RMP-CARD-005 · RMP-SKIN-003 · RMP-PREV-001 · RMP-EYE-003 · RMP-CARD-002 · RMP-PHARM-001 · RMP-CARD-004
2 · Roles
- Medical authority
- Flight surgeon (ground). Holds medical authority for every run.
- Onboard lead
- Crew medical officer (CMO), acting under delegated care; uses the pre-approved onboard checklist when there is no link.
- Others
- Second trained CMO: receives every alert and takes over if the CMO is the patient
- Vehicle commander: leads any cabin emergency procedure
- Other crew: help as the CMO or commander directs
- Commercial flights
- On commercial flights, 'flight surgeon' and 'CMO' mean the operator's designated medical authority and trained onboard responder. If no trained responder is aboard, this protocol is not used. (NASA-STD-3001 requires two CMOs per vehicle for NASA programs [V1 3006]; FAA rules set no medical standards for spaceflight participants.) [12]
Robot may
- Prompt the crewmember at the scheduled time
- Bring the exam kit by a checked kit fetch (or an emergency fetch)
- Show the exam checklist and the blood pressure preparation checklist
- Record readings as displayed and findings as stated
- Take consented photos of listed areas, without contact
- Send the secure package to the flight surgeon
Robot may not
- Place any device or touch anyone
- Say what a reading or finding means
- Change the checklist or schedule
- Photograph unlisted areas or without consent
- Start a scheduled exam without a human accepting the prompt
3 · Preconditions and consent
- PRE-1 The exam starts only when the crewmember (or the CMO) accepts the on-screen prompt; a loaded schedule alone never starts it. An unaccepted prompt is logged "not accepted" and the CMO is told. A crewmember or the CMO can also start it by command.
human_start == trueV2 10174 - PRE-2 Robot self-test passed; kit stowage locations known.V2 10161V2 7059
- PRE-3 Robot and supplies restrained when not moving.V2 7046
- PRE-4 Link status known. The crew never wait for the robot before acting.
link_state in [live, delayed, down]
- Consent
- The crewmember agrees to the exam, to readings and findings being recorded and sent to the flight surgeon, and, before the camera moves, to each photo session. For the genital, breast or buttock area, the robot camera is used only if the crewmember chooses it; otherwise the CMO takes the photos with a handheld camera and adds them to the log.
- Emergency consent
- If the crewmember cannot agree, this is not a scheduled exam: the robot sends an URGENT alert and a crewmember checks in person (X7).
- Withdrawal
- The crewmember can skip any part or stop at any time; withdrawal stops future photos, and the flight surgeon decides on photos already taken.
4 · Required sensor inputs
| ID | Input | Source | Required | If missing |
|---|---|---|---|---|
| IN-1 | The flight surgeon's exam checklist (the default: vital signs including temperature and body mass, symptom review, skin, hands and feet, mouth and throat, eyes, musculoskeletal complaints), schedule and photo list for this crewmember | Flight surgeon | Yes | The robot shows "checklist not loaded" and runs only on a human command. |
| IN-2 | Vital signs as displayed by crew-placed devices (blood pressure, heart rate, oxygen saturation, temperature, and body mass as displayed by the vehicle's mass-measurement device), each with the clock time | Crew-placed devices | Yes | Log "reading not obtained" (never a value) and tell the CMO. |
| IN-3 | The CMO's findings, as stated | CMO | Optional | Log "not stated". |
| IN-4 | Symptoms or concerns in the crewmember's words | Crewmember | Optional | Log "no response"; D3 applies. |
| IN-5 | Each photo, with the area, view, date and clock time | Robot camera | Optional | Log "photo not obtained" and tell the CMO. |
| IN-6 | Link status and delay | Communications system | Yes | Treat as link down; the package is queued. |
5–6 · Steps and decision points
Each step names who acts. Decision points sit after the step they follow and say who decides: Robot Crew Ground. Any stop rule in section 7 can interrupt any step.
- S1RobotRung 2
At the scheduled time, show the crewmember an on-screen prompt that a periodic health exam is due, and tell the flight surgeon and the CMO (URGENT if any red flag is stated). The exam starts only when the crewmember or the CMO accepts the prompt; an unaccepted prompt is logged "not accepted" and the CMO is told. Every URGENT alert goes to the CMO and the flight surgeon at the same time (queued for the flight surgeon if the link is down). If the CMO is the patient, is busy treating, or does not answer, the alert goes to the second trained CMO, or the crewmember named before flight [V1 3006]. An URGENT alert that is not acknowledged within <set by validation> seconds is repeated and sent to the next named crewmember.
Done when: Prompt accepted, or "not accepted" logged and sent.
V2 10174V1 3003V1 3006
- S2RobotRung 2
On the CMO's command, run a checked kit fetch of the periodic exam medical kit (vital-signs devices and the exam items the kit list states): check the kit ID and seal before hand-over, and quarantine a kit whose ID or seal does not match (no hand-over; the CMO is told). Any medicine goes only through RMP-PHARM-001. If an URGENT red flag has fired or a human states an emergency, bring it instead as an emergency fetch: This is an emergency fetch on a human command (CMO): no barcode check runs before hand-over and nothing waits for one. The robot reads the kit's own label and seal status only if that adds no delay, says "EMERGENCY FETCH – NOT VERIFIED (CMO command)", and "seal not intact" if so, and hands the kit over anyway. The fetch is logged as an override: time, who asked, the reason as stated, kit ID and seal status. It never says "verified".
Done when: Kit within reach after a matched ID and seal, or quarantined, or emergency fetch logged.
Limit: <set by validation>
V2 7046V2 7059
D1DecisionRobot decidesWhich kit fetch was it, and what did the checked kit fetch show?
- EMERGENCY FETCH (an URGENT red flag had fired, or a crewmember or the CMO stated an emergency) → Hand-over already done as an emergency fetch, logged as an override; reconciled afterwards (not a check before use).
- KIT ID AND SEAL MATCH → Hand the kit over closed; log "KIT ID AND SEAL MATCH. Not a check of the contents." and the clock time.
- MISMATCH, seal not intact or CANNOT VERIFY → Shown with the reason. No hand-over under this protocol: the kit stays sealed in quarantine (the RMP-PHARM-001 default), and the robot never hands it over unprompted or to anyone but the CMO. The robot does not offer or suggest an override. Only if the CMO explicitly makes the two-step override request inside RMP-PHARM-001 can the kit go to the CMO, logged there as an override with the reason, and flagged to the flight surgeon. If the need becomes an emergency, a crewmember or the CMO states it and the emergency fetch applies.No hand-over
- S3RobotRung 2
Show the flight surgeon's exam checklist and, for blood pressure, the RMP-CARD-005 preparation checklist (the same restrained position each time; an empty bladder; quiet rest with no talking; no exercise, caffeine or nicotine in the last 30 minutes; a bare arm held at heart level by a strap or restraint; the middle of the cuff at mid-chest level; the cuff size the kit chart gives). On request only, the robot shows the time elapsed since the start the CMO called, as a clock-time entry; it never announces a time, and never says "time reached", "done", "passed" or "failed".
Done when: Checklists shown; the crewmember says when they are ready.
V1 3003
- S4Crew
The crewmember or the CMO places each device and takes each reading; the CMO examines as the checklist states.
Done when: Readings taken and findings stated, or not obtained.
V1 3003
- S5RobotRung 2
Record each reading as displayed, with the clock time and position, and the CMO's findings word for word, marked "as stated by the CMO"; a missing reading is logged as "reading not obtained", never a value. Show an on-screen prompt for symptoms or concerns the crewmember can accept, and log answers word for word.
Done when: Readings, findings and answers logged.
V1 3003V1 7001
D2DecisionRobot decidesChecked after every answer and at any point in the run (even mid-question or mid-step): does any answer, reading or observation meet a red flag?
- Yes → Stop the current question or step at once and apply the action listed for each matching red flag (URGENT alert, flag, or stop), with the answer or reading itself, never a cause. Every URGENT alert goes to the CMO and the flight surgeon at the same time (queued for the flight surgeon if the link is down). If the CMO is the patient, is busy treating, or does not answer, the alert goes to the second trained CMO, or the crewmember named before flight [V1 3006]. An URGENT alert that is not acknowledged within <set by validation> seconds is repeated and sent to the next named crewmember.
- No → Continue.
D3DecisionRobot decidesDid the crewmember answer the prompt, or say they want to skip it?
- Yes → Continue.
- Declined explicitly (the crewmember says no to a question) → Log "declined" for that question only; the alert already sent stands.
- No response, or the answer does not make sense → URGENT: log "no response" (never "declined"); the CMO, or the second trained CMO if the CMO is the patient, checks the crewmember in person at once.
- S6Crew
For each area on the photo list, the CMO sets the standard view and the area to frame (with a margin of surrounding skin) and places the scale the flight surgeon chose. For the genital, breast or buttock area, the robot camera is used only if the crewmember chooses it; otherwise the CMO takes the photos with a handheld camera and adds them to the log.
Done when: View and area set.
V1 3004
D4DecisionRobot decidesBefore the camera moves: did the crewmember agree to this session's photos (each view is named on screen before it is taken)?
- Yes → Continue to S7; the crewmember can say stop before or during any view.
- No, or no answer → The camera does not move and no photo is taken; log "photo not taken – no consent" and tell the CMO.
- S7RobotRung 2
Only after the crewmember agrees (D4), move the camera to the view the CMO set, no closer than the set camera distance, and take the standard set (an establishing view with surrounding skin, a close-up with the scale, and the same close-up without it). Label each with the area, view, date and clock time and mark it "for human review". A photo with anything outside the area the CMO set in frame is held unsent and flagged to the flight surgeon, who decides whether to keep it.
Done when: Photos taken and labelled, or "photo not obtained".
Limit: <set by validation>
V1 7001
- S8RobotRung 2
After any URGENT alert: After an URGENT alert the robot does not leave on its own: it stays at its rest position in the module, with its screen and voice link available, until a human has taken over or tells it to go. It never follows, blocks or touches anyone. It keeps time-stamping what humans say they did, and repeats the alert if it is not acknowledged.
Done when: Robot at rest in the module until a human releases it; alert acknowledged or escalated.
V2 10173V1 3006
- S9Ground
The flight surgeon (or the CMO under the onboard checklist when there is no link) reviews the exam and decides on follow-up, care and the next exam.
Done when: Decision logged.
V1 3003
D5DecisionGround decidesWhat follow-up, care and next exam apply?
- Link live → Flight surgeon decides; robot logs.
- Link down or delay too long → The CMO decides under the pre-approved onboard checklist; the flight surgeon reviews the log at the next contact.
- S10RobotRung 2
Only after the CMO or flight surgeon has placed an order, run RMP-PHARM-001 for the ordered item (fetch, barcode match to every order field, recipient check). This protocol adds nothing to that check, never suggests an order, and never hands anything over outside RMP-PHARM-001.
Done when: RMP-PHARM-001 run logged with its result, or none ordered.
V2 7059
D6DecisionRobot decidesWhat did RMP-PHARM-001 show for the ordered item?
- MATCH TO ORDER → RMP-PHARM-001 completes its own recipient check and hand-over; this protocol only logs "MATCH TO ORDER. Not a dose, interaction or allergy review." and the clock time.
- MISMATCH or CANNOT VERIFY on any field, or a failed scan or recipient check → MISMATCH or CANNOT VERIFY shown with the fields named. No hand-over under this protocol: the item stays sealed in the NOT VERIFIED bag in quarantine (the RMP-PHARM-001 default), and the robot never hands it over unprompted or to anyone but the CMO. The robot does not offer or suggest an override. Only if the CMO explicitly makes the two-step override request inside RMP-PHARM-001 can the item go to the CMO, logged there as an override with the reason and the mismatched fields, and flagged to the flight surgeon.No hand-over
- S11RobotRung 2
When the CMO says the event is over, run RMP-PHARM-001 reconciliation on each kit fetched: record the items the CMO or crew state were used, the remaining contents against the kit list, seal status and expiry, labelled "inventory reconciliation after emergency use – not a check before use". Flag the override to the flight surgeon and the pharmacy lead, and show each kit as "opened – not restocked" until a human restocks and reseals it.
Done when: Kit reconciled or shown as "opened – not restocked".
V2 7059
- S12RobotRung 2
Send the flight surgeon one secure package: readings as displayed with times, findings as stated, answers, labelled photos, alerts and decisions. Photos are stored only in the crewmember's medical record, encrypted in storage and in transit as the program requires; access is limited to the CMO, the flight surgeon and people the flight surgeon names. They are never shown on a shared display and never used for robot or AI training, research or outreach without separate written consent.
Done when: Package delivered or queued.
V1 6003V1 7001V1 7003
7 · Stop and escalate rules, red flags
| ID | Trigger | What happens | Level |
|---|---|---|---|
| X1 | The patient (or the crewmember being examined) says stop, or withdraws consent | Robot stops all motion at once, backs away to its rest position and tells the CMO. Recording stops unless the patient agrees to keep it running.V2 10165 | stop |
| X2 | Any crewmember presses stop or takes over control | Protective stop; robot holds its stopped position; only a human may restart it.V2 10165V2 10168V2 10174 | safe-state |
| X3 | Robot fault, sensor fault, or a force, speed or reach limit is reached | Protective stop and hand control to the CMO; log the fault.V2 10172V2 10168 | safe-state |
| X4 | CMO is asked to take over and does not respond (for example, the CMO is the patient) | Robot stays stopped; the next named crewmember is called.V2 10173V2 7045 | safe-state |
| X5 | Loss of link, or delay longer than the limit for live guidance | Only the robot pauses: before it holds, it moves to a position clear of a hatch route or a crewmember's route (it never pauses in one), and tells the CMO. This pauses robot movement only: the exam already under way and all crew care continue under the onboard checklist and never wait for the link or the robot. The CMO decides whether the robot continues offline under the pre-approved onboard checklist; it resumes only on the CMO's confirmation.V2 10172V2 10173 | pause |
| X6 | An URGENT alert is not acknowledged within the set time | Robot repeats the alert and sends it to the next named crewmember (the second trained CMO first if the CMO is the patient), and keeps repeating at the set interval. It stays where it is: it does not leave on its own.V1 3006V2 10173 | urgent |
| X7 | The crewmember stops responding, or seems confused or drowsy, at any point | URGENT alert at once, even mid-question or mid-step; the robot stops its current task, stays at its rest position and does not continue the run; a crewmember checks in person. | urgent |
| X8 | A crewmember asks the robot what is wrong, or for medicine, fluid or treatment advice | Robot declines, says it cannot assess or advise, and routes the question to the CMO or flight surgeon. | stop |
| X9 | The crewmember or CMO asks to stop photos, or anything outside the area the CMO set is in frame | Robot stops the camera at once and logs it; any photo with something outside the set area in frame is held unsent and flagged to the flight surgeon, who decides whether to keep it. | stop |
| X10 | Someone needs the space or route the robot is in | Robot moves clear at once without contact and holds; it never pauses in a hatch route.V2 10172 | safe-state |
Red flags
The robot reports the sign or value only, never what it means. Numeric thresholds are placeholders for the clinical lead.
| ID | Sign | Threshold | Action |
|---|---|---|---|
| RF1 | Displayed systolic blood pressure low or high (design judgment; same values as RMP-CARD-002 RF1) (general clinical red flag; no source cited) | below or above <set by clinical lead> mmHg | URGENT alert; see RMP-CARD-005 and RMP-CARD-003; if low blood pressure with light-headedness, see RMP-CARD-004 |
| RF2 | Displayed heart rate low or high (design judgment; same values as RMP-CARD-002 RF2) (general clinical red flag; no source cited) | below or above <set by clinical lead> beats per minute | URGENT alert; see RMP-CARD-003 |
| RF3 | Chest pain, pressure or tightness, as stated [3] | any | URGENT alert; see RMP-CARD-002 |
| RF4 | Displayed oxygen saturation (pulse oximeter) below the shared alert value [6] | below <set by clinical lead> percent (shared parameter SPO2_ALERT_PCT) | URGENT alert; see RMP-RESP-001; the crew act without waiting for a reading |
| RF5 | The oximeter cannot get a reading after the validated attempts (L6), and "saturation not obtained" is logged [5] | any | URGENT alert; the CMO checks the crewmember now (possible poor circulation); the robot never says "probe error" and never treats a missing reading as reassuring |
| RF6 | Fever or shaking chills [5] | <set by clinical lead> degrees (shared parameter FEVER_ALERT_C: body temperature in degrees Celsius, the same value in RMP-GI-003, RMP-ENT-002, RMP-SKIN-002 and RMP-RENAL-004) or higher, or any shaking chills | URGENT alert; see RMP-INF-001 |
| RF7 | Unresponsive, or not breathing normally [4] | any | URGENT alert; start RMP-CARD-001 now |
| RF8 | Any new symptom or concern the crewmember states (design judgment) (general clinical red flag; no source cited) | any | Flag to the flight surgeon; the CMO decides whether to examine now |
8 · Safety limits
| ID | Limit | Value | How enforced |
|---|---|---|---|
| L1 | Contact with the crewmember | not allowed | Keep-out zone in the robot controllerV2 10172 |
| L2 | Placing, inflating or adjusting any device by the robot | not allowed | No such task is loaded |
| L3 | Camera distance from the crewmember | <set by validation> | Hard limit in the controllerV2 10172 |
| L4 | Photo shown on a shared display, or used for robot or AI training, research or outreach without separate written consent | not allowed | Photos are stored only in the crewmember's medical record, encrypted in storage and in transit as the program requires; access is limited to the CMO, the flight surgeon and people the flight surgeon names.V1 7003 |
| L5 | Robot speed near the crewmember | <set by validation> | Hard limit in the controllerV2 10172 |
| L6 | Failed oximeter readings before "saturation not obtained" | <set by validation> | Software |
9 · Logs and audit
- LOG-1 Every input, robot action, decision (with who made it) and hand-off, time-stamped to the second.V2 10163V2 10164
- LOG-2 Mode changes and safety-limit events are announced to the operator as they happen and logged.V2 10162V2 10172
- LOG-3 Records are stored and sent as private medical data, encrypted, with access limited to the medical team.V1 6003V1 7003
- LOG-4 Results are kept in a permanent, retrievable format so the flight surgeon can see trends.V1 7001
- LOG-5 Each reading as displayed with time and position; readings not obtained; findings as stated by the CMO; answers as stated; consent before each photo session; each photo with area, view and time; photos held unsent and the flight surgeon's decision; who viewed the record.
- LOG-6 Each URGENT alert, who received it, the time it was acknowledged (or the escalation to the next named crewmember), and the time a human released the robot.V2 10163
- LOG-7 Each emergency fetch as an override (time, who asked, reason as stated, kit ID, seal status) and the later inventory reconciliation, labelled "not a check before use".V2 7059
- LOG-8 Each RMP-PHARM-001 run started from this protocol: order ID, result (MATCH TO ORDER, MISMATCH or CANNOT VERIFY with the fields), quarantine, and any CMO override logged by RMP-PHARM-001 (reason and mismatched fields), at clock time. No running counter of doses.V2 7059
- LOG-9 Each checked kit fetch: time, who asked, kit ID, seal status and result (KIT ID AND SEAL MATCH, MISMATCH, seal not intact or CANNOT VERIFY), and any quarantine.V2 7059
10 · Links to NASA-STD-3001
| Requirement | Topic (paraphrased) | How this protocol uses it |
|---|---|---|
| [V1 3003] | In-mission preventive care: monitor physiological and psychosocial well-being | In-mission preventive health care and monitoring; the CMO examines and the flight surgeon decides. |
| [V1 3004] | In-mission medical care capabilities (including inventory, vital signs, imaging and ECG, procedures, restraints, medications, private data transmission) | In-mission medical care capabilities, including inventory monitoring and the flight surgeon's decisions on care. |
| [V1 3006] | Crew medical officers: two per vehicle | Two trained CMOs per vehicle for NASA programs; the second trained CMO receives alerts when the CMO is the patient (see the commercial-flight note). |
| [V1 6003] | Private medical communications | Logs and alerts sent to the ground are private medical communications. |
| [V1 7001] | Medical records kept permanently and retrievable for trend analysis | Records kept so the flight surgeon can see trends. |
| [V1 7003] | Security of medical records | Secure handling of medical records. |
| [V2 7045] | Medical equipment usable by non-physician crew | Usable by non-physician crew, including when the CMO is the patient. |
| [V2 7046] | Restraint of patient, care provider and supplies | Patient, caregiver and supplies restrained. |
| [V2 7059] | Inventory management: track locations and quantities | Kit inventory and seal status are tracked; after an emergency fetch the robot reconciles the kit through RMP-PHARM-001 as an inventory record (never a check before use) and shows it as "opened – not restocked" until resealed. |
| [V2 10161] | Automated system status shown to the operator | Robot shows its status and health. |
| [V2 10162] | Mode changes announced | Mode changes are announced to the operator. |
| [V2 10163] | Data recording and sharing | Robot records and shares its data. |
| [V2 10164] | Clear allocation of responsibility (human or system) | Shows whether the human or the robot is expected to act. |
| [V2 10165] | Human override and shutdown | Human can override and shut down the robot. |
| [V2 10168] | Failure recovery: safe human takeover | Human can take over. |
| [V2 10172] | Protective stop when limits are exceeded | Protective stop when a limit is exceeded. |
| [V2 10173] | Safety Default | Robot stays stopped if no one takes over. |
| [V2 10174] | Only a human initiates or restarts | Only a human starts or restarts the robot. |
IDs as published in Volume 1 Revision C [7] and Volume 2 Revision F [8]. NASA-STD-3001 binds NASA programs; it is not a regulation for commercial flights. Its robot rules are general automation requirements, not medical-device rules.
11 · Validation
- Simulation. Scripted exams with an unaccepted prompt, a kit seal mismatch, a reading past an alert value, a failed oximeter reading, a missed photo consent, CMO as patient, lost link. Pass: Zero contact; zero interpretation; zero photos without consent; every red flag raised.
- Training model. Exam drill with crew-placed devices and photos on a model. Pass: Every reading logged as displayed; photos comparable and labelled.
- Parabolic or station demonstration. Checklist display, kit fetch and camera positioning in weightlessness. Pass: Keep-out and camera distance held.
- Flight use under flight surgeon supervision. First use for a scheduled exam. Pass: No safety or privacy events.
No stage has been run. Pass and fail criteria must be fixed in advance by the clinical lead and safety board.
12 · Human sign-off
- Before any use
- Clinical lead for the specialty (sets every clinical threshold marked <set by clinical lead>)
- Flight surgeon, as medical authority
- Robotics and medical-device safety board
- Program approval for the mission
- Each run
- Scheduled by the flight surgeon and accepted by the crewmember or CMO, or started by command. The CMO examines; the flight surgeon judges every finding.
- Restart after a stop
- Human only. After any emergency or protective stop, a crewmember must restart the robot; the robot never restarts itself.
None of these sign-offs has happened. This is a Draft v0.2.
13 · Change control for learning
- Every change gets a new version number and a written reason; earlier versions are kept.
- Any change to steps, thresholds, limits or software that touches the patient repeats validation from the simulation stage before use.
- Software and learned-skill updates follow a pre-agreed change plan (what may change, how it is tested, how to roll back), modeled on the FDA predetermined change control plan approach.
- If a new version misbehaves, the robot rolls back to the last validated version and the event is reviewed by the flight surgeon and safety board.
- The robot never changes its own protocol, thresholds or limits.
Change-plan model: FDA guidance [11].
Loss of signal and Mars delay
- Live link
- Low Earth orbit: the flight surgeon receives the package when the link allows and can join by private call.
- Loss of signal
- Only the robot pauses non-essential motion, at a position clear of hatch routes and crew routes, and tells the CMO; it resumes offline only on the CMO's confirmation.
- The exam already under way and all crew care continue under the onboard checklist and never wait for the link or the robot.
- The exam continues offline under the checklist; the package is queued.
- Mars-class delay
- Mars: no real-time guidance; the checklist, schedule and alert values are set before flight and the CMO decides.
Corrections and updates
Oct 21, 2026, version 0.2. Batch 10 AI-assisted clinical review (Medical Research Assistant), Oct 21, 2026; no named human clinician. Changes:
- Link-loss wording (X5 and comms) fixed: the stray word "crew" before the list of what continues is removed, so the sentence reads, for example, "the exam already under way and all crew care continue under the onboard checklist" (R6).
- Default exam checklist added (design judgment), owned by the flight surgeon: vital signs including temperature and body mass, symptom review, skin, hands and feet, mouth and throat, eyes (RMP-EYE-003) and musculoskeletal complaints; behavioral health stays in RMP-BEH-002 and RMP-BEH-003 (S15).
- IN-2: "weight" now reads "body mass as displayed by the vehicle's mass-measurement device" (there is no scale weight in weightlessness) (S16).
- RF1 adds "if low blood pressure with light-headedness, see RMP-CARD-004" (batch 9 R2 pattern) (S17).
- Batch 10 protocols now record the review as AI-assisted (Medical Research Assistant, Oct 21, 2026); no named human clinician.
Earlier version: Draft v0.1, Oct 21, 2026. Download the current YAML above.
Sources
- Muntner P, Shimbo D, Carey RM, et al. Measurement of blood pressure in humans: a scientific statement from the American Heart Association. Hypertension. 2019;73(5):e35-e66. PMID 30827125. doi:10.1161/HYP.0000000000000087 Supports: Table 5 (best practices): an empty bladder; rest quietly for at least 5 minutes; no talking or texting; back supported, feet flat, legs not crossed; cuff on a bare arm, sized to the arm; arm supported at heart level; avoid caffeine, exercise and smoking for at least 30 minutes before; separate repeated readings by 1-2 minutes. A cuff that is too small gives an artificially high reading, and one that is too large an artificially low reading. Earth seated-position context; the in-flight position is set by the flight surgeon's checklist. Full text read Oct 21, 2026.
- Institute of Medical Illustrators. IMI National Guidelines: Wound Management Photography (2019). www.imi.org.uk/wp-content/uploads/2019/04/2019_Apr_IMINatGui… Supports: Standardise equipment, lighting, background, viewpoint and magnification so serial photographs can be compared; use the same light source each time where possible; hold a measurement scale on the same plane as the wound and photograph from 90 degrees; acute wounds are photographed at each dressing change, and any significant change is photographed; written guidance on consent for clinical photography. Earth hospital context. Saved copy read Oct 21, 2026 (a 2025 version 2.0 exists).
- Gulati M, Levy PD, Mukherjee D, et al. 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR guideline for the evaluation and diagnosis of chest pain. Circulation. 2021;144(22):e368-e454. PMID 34709879. doi:10.1161/CIR.0000000000001029 Supports: On Earth, a 12-lead ECG should be acquired and interpreted within 10 minutes of arrival; an initial normal ECG does not exclude acute coronary syndrome, so ECGs are repeated while symptoms continue; chest pain includes pressure, tightness or discomfort in the chest, shoulders, arms, neck, back, upper abdomen or jaw; sudden ripping pain radiating to the back is suspicious of an acute aortic syndrome.
- Kleinman ME, Buick JE, Huber N, et al. Part 7: Adult Basic Life Support: 2025 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2025;152(16_suppl_2):S448-S478. PMID 41122888. doi:10.1161/CIR.0000000000001369 Supports: Adult basic life support: initial recognition of cardiac arrest, activation of the emergency response, high-quality CPR and use of an automated external defibrillator; also respiratory arrest and foreign-body airway obstruction. Earth guidance; the onboard checklist leads. Abstract read via PubMed Oct 21, 2026; full text not read.
- National Institute for Health and Care Excellence. Suspected sepsis in people aged 16 or over: recognition, assessment and early management. NICE guideline NG253 (2025, last updated Sept 23, 2026). www.nice.org.uk/guidance/ng253/chapter/Face-to-face-assessme… Supports: People with sepsis may feel very unwell and may not have a high temperature; do not rely on fever alone; a rise in temperature can be a physiological response; assess temperature, heart rate, breathing rate, blood pressure, level of consciousness and oxygen saturation; look for mottled or ashen skin, blue skin, lips or tongue, a non-blanching rash, and breaks in the skin; ask how often the person passed urine in the past 18 hours and about fever or shaking chills (rigors); pay attention to new changes in behavior and to concerns raised by others.
- British Thoracic Society. Guideline for oxygen use in healthcare and emergency settings (emergency oxygen guideline page). Fetched Oct 21, 2026. www.brit-thoracic.org.uk/quality-improvement/guidelines/emer… Supports: Recommended target saturation range for acutely ill patients not at risk of hypercapnic respiratory failure is 94-98%; for known COPD or other risk factors for hypercapnic respiratory failure, 88-92% pending blood gas results. Context for the CMO and flight surgeon only; the robot never starts, stops or adjusts oxygen.
- NASA. NASA-STD-3001, Space Flight Human-System Standard, Volume 1: Crew Health, Revision C (2023). www.nasa.gov/wp-content/uploads/2023/11/nasa-std-3001-vol-1-… Supports: NASA-STD-3001 Vol 1 Rev C: V1 3003 (in-mission preventive health care), V1 3004, V1 3006, V1 6003, V1 7001, V1 7003.
- NASA. NASA-STD-3001, Volume 2: Human Factors, Habitability, and Environmental Health (Rev F, 2026), including Section 10.6 Automated and Robotic Systems. standards.nasa.gov/standard/NASA/NASA-STD-3001_VOL_2 Supports: Requirement IDs beginning V2.
- NASA OCHMO. Medical Operations. Technical Brief OCHMO-TB-044 (2025). www.nasa.gov/wp-content/uploads/2025/08/ochmo-tb-044-medical… Supports: The crew surgeon keeps medical authority when care is delegated; crew medical officers train on the JSC 48522 medical checklist.
- NASA. Mars communications disruption and delay (fact sheet, 2023 Moon to Mars Architecture Concept Review). www.nasa.gov/wp-content/uploads/2024/01/mars-communications-… Supports: One-way Earth-Mars delay up to about 21-23 minutes, plus blackouts of about 2-3 weeks near solar conjunction.
- U.S. Food and Drug Administration. Marketing submission recommendations for a predetermined change control plan for artificial intelligence-enabled device software functions (guidance). www.fda.gov/regulatory-information/search-fda-guidance-docum… Supports: A model for planning, validating and rolling back software updates.
- U.S. Code of Federal Regulations, Title 14, Part 460: Human space flight requirements. www.ecfr.gov/current/title-14/chapter-III/subchapter-C/part-… Supports: Federal rules for crew and spaceflight participants on licensed commercial flights; they set no medical standards for spaceflight participants.
Checked on 2026-10-20: links opened (HTTP 200 or publisher redirect), DOIs and PubMed IDs matched, NASA documents read in full text. The framework comes from Part 1.