# RMP-SKIN-001 Wound cleaning and dressing: hold and pass supplies, photo documentation (crew leads)
# Version 0.7 (Draft). CONCEPTUAL. NOT FOR CLINICAL USE.
# Space Medicine Foundation robot-readable protocol library. Format: https://spacemedicinefoundation.org/robotic-medicine/protocols/schema/
# Every threshold marked <set by ...> must be set by the named owner (see the schema) before any use.
schema_version: '0.3'
id: RMP-SKIN-001
slug: rmp-skin-001
title: 'Wound cleaning and dressing: hold and pass supplies, photo documentation (crew leads)'
version: '0.7'
status: draft
conceptual: true
not_for_clinical_use: true
category: skin
tier: 1
max_autonomy: 2
rung_note: >-
  Raised from rung 1 in the outline for fetching, passing supplies and photo positioning. Holding a limb
  is rung 1 and is its own step (S5), so the build checks it: the CMO places the limb and the robot only
  holds it still while the CMO keeps a hold command active.
missions:
- leo
- commercial
- moon
- mars
updated: '2026-10-21'
review:
  state: reviewed-ai-assisted
  requested: '2026-10-20'
  reviewed: '2026-10-20'
  human_clinician_review: false
  text: >-
    AI-assisted clinical and source review by the Medical Research Assistant, Oct 20, 2026; no named human
    clinician. All corrections from that review are applied in this version (see Corrections). Written
    with AI assistance; sources self-verified.
fixed_rules:
  flight_surgeon_is_medical_authority: true
  cmo_acts_under_delegated_care: true
  human_starts_and_restarts_robot: true
  robot_never_diagnoses: true
  no_drug_or_fluid_advice_by_robot: true
  safe_state_on_fault_or_no_response: true
  lost_link_pause_then_cmo_decides: true
robot_lockouts:
  diagnosis: true
  drug_or_fluid_advice: true
  starting_stopping_or_adjusting_oxygen_or_any_medicine: true
  self_start_or_self_restart: true
  changing_own_protocol_thresholds_or_limits: true
  handing_over_a_mismatched_item_as_verified: true
result_language:
  use:
  - photo recorded
  - measured (for human review)
  - flagged for human review
  never:
  - normal
  - no problem found
  - all clear
  - negative
  - any diagnosis or cause
  - healing well
  - infected
  - not infected
scope:
  summary: >-
    For a minor wound (cut, scrape or skin tear), the CMO cleans and dresses it while the robot brings
    the kit, holds a containment pad or bag, passes items on request, holds the limb steady if asked,
    and takes standard photos with a scale and color reference before and after dressing and at each dressing
    change.
  why: >-
    In weightlessness, fluid and debris containment must be planned for: blood tends to dome at the wound,
    but droplets can break free. Standard, repeatable photos let the flight surgeon follow a wound across
    days. (Skin rashes, a different problem, were the most reported clinical event in one study of 46
    long-duration crew; rashes are covered by RMP-SKIN-004; RMP-SKIN-003 is the wound photo log.)
  covers:
  - Clean, minor cuts, scrapes and skin tears
  - Follow-up photos at each dressing change
  locked_out:
  - Cleaning, closing or dressing the wound itself
  - Handling sharps
  - Choosing a dressing, ointment or any medicine
  - Judging infection or healing
  - >-
    Deep, gaping or heavily bleeding wounds, and dirty or major wounds: punctures, crush injuries, bites,
    embedded foreign material or contaminated wounds (crew trauma care; see RMP-MSK-001)
  - Any advice on tetanus vaccination or immune globulin (decided by the CMO and flight surgeon)
  - Burns (RMP-SKIN-002) and eye wounds (RMP-EYE-001)
  - Suturing (research only, RMP-SKIN-005)
  related:
  - RMP-SKIN-002
  - RMP-SKIN-003
  - RMP-MSK-001
  - RMP-INF-002
roles:
  medical_authority: Flight surgeon (ground). Holds medical authority for every run.
  onboard_lead: >-
    Crew medical officer (CMO), acting under delegated care; uses the pre-approved onboard checklist when
    there is no link.
  others:
  - 'Patient: can stop the robot at any time'
  - Second crewmember if available (wears eye protection)
  robot_may:
  - Fetch the wound kit, containment supplies and camera
  - Hold an absorbent pad or bag under the wound
  - Pass items on request (no sharps)
  - Hold a limb still after the crew place it, within force limits
  - Take standard photos and log supplies used
  robot_may_not:
  - Touch the wound
  - Handle sharps
  - Choose any dressing or medicine
  - Say a wound is infected, not infected or healing
  - Advise on tetanus vaccination
  - Photograph the face unless the wound is on the face and the patient agrees
  commercial: >-
    On commercial flights, 'flight surgeon' and 'CMO' mean the operator's designated medical authority
    and trained onboard responder. If no trained responder is aboard, this protocol is not used. (NASA-STD-3001
    requires two CMOs per vehicle for NASA programs [V1 3006]; FAA rules set no medical standards for
    spaceflight participants.)
preconditions:
- id: PRE-1
  text: The CMO judged the wound minor and started the run.
  refs:
  - V2 10174
- id: PRE-2
  text: Patient, CMO and supplies restrained.
  refs:
  - V2 7046
- id: PRE-3
  text: Robot self-test passed; gripper surfaces cleaned.
  refs:
  - V2 10161
- id: PRE-4
  text: Bleeding controlled with pressure before the robot comes close.
- id: PRE-5
  text: Link status and delay known.
- id: PRE-6
  text: Patient, CMO and helper wear eye protection; absorbent containment in place before any irrigation.
  check: eye_protection_on == true and containment_ready == true
consent:
  standard: >-
    Patient agrees by voice or touch, including to photos; logged. Photos frame the wound and reference
    card only.
  emergency: >-
    If the patient cannot agree, the robot only fetches and passes supplies on the CMO's decision; photos
    wait for consent unless the flight surgeon decides otherwise.
  withdrawal: Patient can stop photos or robot help at any time.
inputs:
- id: IN-1
  name: Camera image with scale and color reference card
  source: Robot camera
  required: true
  if_missing: CMO takes photos with a handheld camera and the reference card.
- id: IN-2
  name: Wound location, time and how it happened
  source: Entered by the CMO
  required: true
  if_missing: Log "not entered".
- id: IN-3
  name: Tetanus immunization date
  source: Medical record (shown to the CMO and flight surgeon; the robot does not advise)
  required: true
  if_missing: Show "tetanus status unknown" to the CMO and flight surgeon.
- id: IN-4
  name: Pain score (0-10)
  source: Patient
  required: false
  if_missing: Log "not answered".
- id: IN-5
  name: Grip force and position while holding a limb
  source: Robot force sensors
  required: true
  if_missing: Do not hold the limb.
- id: IN-6
  name: Supplies used
  source: Barcode scan or CMO entry
  required: false
  if_missing: CMO enters after the procedure.
- id: IN-7
  name: Link status and delay
  source: Communications system
  required: true
  if_missing: Treat as link down.
steps:
- id: S1
  actor: robot
  rung: 2
  action: >-
    On request, bring the wound kit, eye protection, containment supplies and camera; restrain them by
    the patient. Show the CMO the tetanus immunization date from the medical record (shown only; the robot
    gives no advice).
  success: Kit restrained at the patient; tetanus record shown.
  refs:
  - V2 7046
- id: S2
  actor: robot
  rung: 2
  action: Hold an absorbent pad or containment bag under the wound area.
  success: Pad in place; CMO confirms.
- id: S3
  actor: robot
  rung: 2
  action: >-
    Take a "before" photo with the scale and color card; label it. Frame the wound and reference card
    only; exclude the face unless the wound is on the face and the patient agrees.
  success: Photo passes the focus and framing check.
  refs:
  - V1 6003
- id: S4
  actor: crew
  action: If a limb needs holding, the CMO places it and starts a hold command.
  success: Limb placed; hold command active, or no hold needed.
  refs:
  - V2 10164
- id: S5
  actor: robot
  rung: 1
  action: >-
    Hold the limb still only while the CMO keeps the hold command active, within force limits; release
    at once on X6 or when the command ends.
  success: Limb held steady, or released on command.
  limit: <set by validation>
  refs:
  - V2 10165
  - V2 10172
- id: S6
  actor: robot
  rung: 2
  action: Pass items on request during cleaning and dressing (never sharps).
  success: Each requested item handed over.
- id: S7
  actor: crew
  action: CMO cleans the wound.
  success: CMO reports cleaning complete.
  refs:
  - V2 7046
- id: S8
  actor: crew
  action: CMO chooses and applies the dressing.
  success: Dressing applied.
- id: S9
  actor: robot
  rung: 2
  action: Take an "after" photo with the same framing; log supplies used.
  success: Photo stored; inventory updated.
  refs:
  - V2 7059
- id: S10
  actor: robot
  rung: 2
  action: Bag waste per the biohazard procedure; clean robot surfaces per the cleaning protocol.
  success: Cleaning logged.
- id: S11
  actor: robot
  rung: 2
  action: >-
    Send photos and the log to the flight surgeon as private medical data, or queue them; set up follow-up
    photo sessions at each dressing change as the flight surgeon directs.
  success: Delivery confirmed or queued; schedule logged.
  refs:
  - V1 6003
  - V1 7001
  - V1 7003
decisions:
- id: D1
  after: S1
  decided_by: crew
  question: >-
    Is the wound beyond minor or dirty: deep, gaping, heavy bleeding, affecting the eye, face, a joint
    or hand function, or a puncture, crush injury, bite, embedded foreign material or a contaminated wound?
  branches:
  - if: 'Yes'
    then: >-
      Stop this protocol; CMO starts trauma care and calls the flight surgeon (RMP-MSK-001). Tetanus status
      and wound type go to the flight surgeon.
  - if: 'No'
    then: Continue.
- id: D2
  after: S3
  decided_by: robot
  question: Did the photo pass the quality check?
  branches:
  - if: 'Yes'
    then: Continue.
  - if: No after <set by validation> tries
    then: Hand the camera to the CMO.
- id: D3
  after: S11
  decided_by: ground
  question: What is the dressing and follow-up plan?
  branches:
  - if: Link live
    then: Flight surgeon decides; robot logs.
  - if: Link down
    then: CMO follows the onboard checklist; flight surgeon reviews photos later.
stop_rules:
- id: X1
  trigger: The patient (or the crewmember being examined) says stop, or withdraws consent
  action: >-
    Robot stops all motion at once, backs away to its rest position and tells the CMO. Recording stops
    unless the patient agrees to keep it running.
  level: stop
  refs:
  - V2 10165
- id: X2
  trigger: Any crewmember presses stop or takes over control
  action: Protective stop; robot holds its stopped position; only a human may restart it.
  level: safe-state
  refs:
  - V2 10165
  - V2 10168
  - V2 10174
- id: X3
  trigger: Robot fault, sensor fault, or a force, speed or reach limit is reached
  action: Protective stop and hand control to the CMO; log the fault.
  level: safe-state
  refs:
  - V2 10172
  - V2 10168
- id: X4
  trigger: CMO is asked to take over and does not respond (for example, the CMO is the patient)
  action: Robot stays stopped; the next named crewmember is called.
  level: safe-state
  refs:
  - V2 10173
  - V2 7045
- id: X5
  trigger: Loss of link, or delay longer than the limit for live guidance
  action: >-
    Only the robot pauses; crew care never waits for the link or the robot. Robot pauses any movement
    in its stopped position and tells the CMO. The CMO decides whether to continue offline under the pre-approved
    onboard checklist; the robot resumes only on the CMO's confirmation. Everything is logged and sent
    to the flight surgeon at the next contact.
  level: pause
  refs:
  - V2 10172
  - V2 10173
- id: X6
  trigger: Patient flinches or reports pain while the limb is held
  action: Robot releases the limb at once and backs away.
  level: stop
  refs:
  - V2 10172
red_flags:
- id: RF1
  sign: Bleeding not controlled by pressure
  threshold: after <set by clinical lead> minutes
  action: 'URGENT: CMO trauma care and flight surgeon call'
- id: RF2
  sign: Crew-reported spreading redness, warmth, swelling, pus or red streaks
  threshold: any
  action: URGENT call to flight surgeon with photos
- id: RF3
  sign: Fever
  threshold: <set by clinical lead> °C or higher
  action: URGENT call; see RMP-INF-001
- id: RF4
  sign: Numbness, weakness, or loss of movement beyond the wound
  threshold: any
  action: URGENT call
safety_limits:
- id: L1
  name: Grip force when holding a limb
  value: <set by validation>
  enforced: Force sensing; release on exceed
  refs:
  - V2 10172
- id: L2
  name: Hold duration
  value: <set by validation>
  enforced: Timer; then release and re-confirm
- id: L3
  name: Robot speed near an open wound
  value: <set by validation>
  enforced: Hard limit
- id: L4
  name: Sharps handling
  value: not allowed
  enforced: Gripper refuses tagged sharps
- id: L5
  name: Limb hold without an active CMO hold command
  value: not allowed
  enforced: Hold releases when the command ends
  refs:
  - V2 10165
logs:
- id: LOG-1
  text: Every input, robot action, decision (with who made it) and hand-off, time-stamped to the second.
  refs:
  - V2 10163
  - V2 10164
- id: LOG-2
  text: Mode changes and safety-limit events are announced to the operator as they happen and logged.
  refs:
  - V2 10162
  - V2 10172
- id: LOG-3
  text: >-
    Records are stored and sent as private medical data, encrypted, with access limited to the medical
    team.
  refs:
  - V1 6003
  - V1 7003
- id: LOG-4
  text: Results are kept in a permanent, retrievable format so the flight surgeon can see trends.
  refs:
  - V1 7001
requirements:
- id: V1 3004
  use: >-
    In-mission care includes performing procedures, recording outcomes and restraints, personal protective
    equipment (biohazard and sharps containment), and privacy considerations.
- id: V1 3006
  use: Two crew medical officers per vehicle for NASA programs (see the commercial-flight note).
- id: V1 6003
  use: Private medical communications.
- id: V1 7001
  use: Photos kept for trend review across dressing changes.
- id: V1 7003
  use: Secure records.
- id: V2 7045
  use: Usable by non-physician crew.
- id: V2 7046
  use: Patient, caregiver and supplies restrained.
- id: V2 7059
  use: Inventory updated with supplies used.
- id: V2 10161
  use: Status shown.
- id: V2 10162
  use: Mode changes are announced to the operator.
- id: V2 10163
  use: Data recorded and shared.
- id: V2 10164
  use: Shows who acts.
- id: V2 10165
  use: Human override.
- id: V2 10168
  use: Human takeover.
- id: V2 10172
  use: Protective stop and release.
- id: V2 10173
  use: Robot stays stopped if no one takes over.
- id: V2 10174
  use: Only a human starts or restarts the robot.
validation:
- stage: simulation
  what: Robot passing, holding and photo tasks in simulation, including fluid release.
  pass: Zero force-limit violations; photos framed consistently.
- stage: training model
  what: Wound-care trainer limbs with simulated fluid.
  pass: Containment success at or above <set by validation>; photo sets judged usable by clinicians.
- stage: Earth analog
  what: Analog crews; photos reviewed remotely.
  pass: Pass criteria set in advance.
- stage: parabolic or station demonstration
  what: Containment pad and passing tasks in weightlessness, without a patient.
  pass: Fluid containment and hand-over work as specified.
signoff:
  protocol:
  - Clinical lead for the specialty (sets every clinical threshold marked <set by clinical lead>)
  - Flight surgeon, as medical authority
  - Robotics and medical-device safety board
  - Program approval for the mission
  restart_after_stop: >-
    Human only. After any emergency or protective stop, a crewmember must restart the robot; the robot
    never restarts itself.
  each_run: >-
    Started by the CMO. Flight surgeon review of photos when the link allows; otherwise at the next contact.
change_control:
- Every change gets a new version number and a written reason; earlier versions are kept.
- >-
  Any change to steps, thresholds, limits or software that touches the patient repeats validation from
  the simulation stage before use.
- >-
  Software and learned-skill updates follow a pre-agreed change plan (what may change, how it is tested,
  how to roll back), modeled on the FDA predetermined change control plan approach.
- >-
  If a new version misbehaves, the robot rolls back to the last validated version and the event is reviewed
  by the flight surgeon and safety board.
- The robot never changes its own protocol, thresholds or limits.
comms:
  live: 'Low Earth orbit: photos and video go to the flight surgeon live.'
  loss_of_signal:
  - Only the robot pauses; crew care never waits for the link or the robot.
  - >-
    The robot pauses any movement and tells the CMO; on the CMO's confirmation it continues under the
    onboard checklist; photos and logs are queued.
  - Follow-up photo sessions continue on the last agreed schedule.
  mars_delay:
  - No live review; the flight surgeon follows the wound through photo packages.
  - Escalation signs and the photo schedule are agreed before flight.
sources:
- key: khanna
  text: >-
    Khanna R, Li Y, Cook M, et al. Surgery for interplanetary space missions. Br J Surg. 2026;113(3):znag005.
  url: https://doi.org/10.1093/bjs/znag005
  doi: 10.1093/bjs/znag005
  pmid: '41823369'
  supports: >-
    Means of fluid and debris containment must be planned for in space surgery; the review also notes
    that fluid management may be less difficult than expected, because blood tends to stay at the wound
    (surface tension makes it dome), though arterial bleeding can form a stream of droplets.
- key: cdctet
  text: >-
    U.S. Centers for Disease Control and Prevention. Clinical guidance for wound management to prevent
    tetanus (updated September 8, 2026).
  url: https://www.cdc.gov/tetanus/hcp/clinical-guidance/index.html
  supports: >-
    Dirty or major wounds include penetrating or puncture wounds, wounds containing dirt, soil, feces
    or saliva (for example bites), and wounds with devitalized tissue such as crush injuries and burns;
    the need for tetanus vaccination or immune globulin depends on the wound type and vaccination history.
- key: crucian
  text: >-
    Crucian B, Babiak-Vazquez A, Johnston S, et al. Incidence of clinical symptoms during long-duration
    orbital spaceflight. Int J Gen Med. 2016;9:383-391.
  url: https://doi.org/10.2147/IJGM.S114188
  doi: 10.2147/IJGM.S114188
  pmid: '27843335'
  supports: >-
    Among 46 long-duration ISS crewmembers, skin rashes were the most reported clinical event in the categories
    studied (infections, allergies, rashes and hypersensitivities), at 1.12 per flight year. Wounds were
    not studied.
- key: tb033
  text: NASA OCHMO. Spaceflight Experience and Medical Care. Technical Brief OCHMO-TB-033 (2023).
  url: https://www.nasa.gov/wp-content/uploads/2023/12/ochmo-tb-033-spaceflight-experience-medical-care.pdf
  supports: >-
    Headaches are more common in spaceflight, with elevated CO2, fluid shifts and pressure changes among
    contributing factors; pre-mission exams include ECG, eye exams and photo documentation of skin.
- key: tb044
  text: NASA OCHMO. Medical Operations. Technical Brief OCHMO-TB-044 (2025).
  url: https://www.nasa.gov/wp-content/uploads/2025/08/ochmo-tb-044-medical-operations.pdf
  supports: >-
    The crew surgeon keeps medical authority when care is delegated; crew medical officers train on the
    JSC 48522 medical checklist.
- key: v1
  text: 'NASA. NASA-STD-3001, Space Flight Human-System Standard, Volume 1: Crew Health, Revision C (2023).'
  url: https://www.nasa.gov/wp-content/uploads/2023/11/nasa-std-3001-vol-1-rev-c-with-signature.pdf
  supports: Requirement IDs beginning V1.
- key: v2
  text: >-
    NASA. NASA-STD-3001, Volume 2: Human Factors, Habitability, and Environmental Health (Rev F, 2026),
    including Section 10.6 Automated and Robotic Systems.
  url: https://standards.nasa.gov/standard/NASA/NASA-STD-3001_VOL_2
  supports: Requirement IDs beginning V2.
- key: marsdelay
  text: >-
    NASA. Mars communications disruption and delay (fact sheet, 2023 Moon to Mars Architecture Concept
    Review).
  url: https://www.nasa.gov/wp-content/uploads/2024/01/mars-communications-disruption-and-delay.pdf
  supports: >-
    One-way Earth-Mars delay up to about 21-23 minutes, plus blackouts of about 2-3 weeks near solar conjunction.
- key: pccp
  text: >-
    U.S. Food and Drug Administration. Marketing submission recommendations for a predetermined change
    control plan for artificial intelligence-enabled device software functions (guidance).
  url: >-
    https://www.fda.gov/regulatory-information/search-fda-guidance-documents/marketing-submission-recommendations-predetermined-change-control-plan-artificial-intelligence
  supports: A model for planning, validating and rolling back software updates.
- key: faa460
  text: 'U.S. Code of Federal Regulations, Title 14, Part 460: Human space flight requirements.'
  url: https://www.ecfr.gov/current/title-14/chapter-III/subchapter-C/part-460
  supports: >-
    Federal rules for crew and spaceflight participants on licensed commercial flights; they set no medical
    standards for spaceflight participants.
corrections:
- date: '2026-10-20'
  version: '0.2'
  source: AI-assisted clinical and source review by the Medical Research Assistant, Oct 20, 2026
  items:
  - >-
    Removed the rash statistic as evidence for wound care; it is now noted as a separate problem (Crucian
    2016 did not study wounds).
  - 'Khanna 2026 wording: containment must be planned for (not "unsolved").'
  - >-
    Dirty or major wounds (puncture, crush, bite, embedded foreign material, contaminated) now escalate
    to trauma care; the tetanus immunization date is shown to the CMO and flight surgeon (CDC wound guidance);
    the robot gives no tetanus advice.
  - 'New PRE-6: eye protection for patient, CMO and helper; containment in place before irrigation.'
  - >-
    Photo privacy: wound and reference card only; the face only if the wound is on the face and the patient
    agrees.
  - >-
    Limb holding is now its own robot step at rung 1 (S5), active only while the CMO holds a hold command,
    so the build checks it.
  - >-
    Loss of link (X5) now means: pause motion, tell the CMO, and continue offline only on the CMO's confirmation
    (fixes the contradiction with the comms branch).
  - >-
    Added a commercial-flight note on who the flight surgeon and CMO are, and a fixed list of robot lockouts
    checked by the build.
- date: '2026-10-21'
  version: '0.2'
  source: Batch 5 editorial (AI-assisted), Oct 21, 2026; batch 4 review item 49
  items:
  - >-
    Inherited stop-rule and requirement wording: "holds a safe position" → "holds its stopped position";
    "stays in its safe state" → "stays stopped"; "take over safely" → "take over"; "Robot stays safe if
    no one takes over" → "Robot stays stopped if no one takes over". Schema level name safe-state and
    never-word list entry "safe" unchanged.
- date: '2026-10-21'
  version: '0.3'
  source: Batch 6 editorial (AI-assisted), Oct 21, 2026
  items:
  - >-
    Requirement use for [V2 10173] changed from "Safe default." to "Robot stays stopped if no one takes
    over." (batch 5 review item 25; editorial, behaviour unchanged).
- date: '2026-10-21'
  version: '0.4'
  source: Batch 7 editorial (AI-assisted), Oct 21, 2026
  items:
  - >-
    Citation labels changed to the site's year-only convention: "(approved for public release <date>)"
    now reads "(YYYY)", and NASA-STD-3001 Volume 2 "Revision F (approved July 14, 2026)" now reads "(Rev
    F, 2026)" (sources: v2). Editorial; no change to steps, thresholds or limits.
- date: '2026-10-21'
  version: '0.5'
  source: Batch 7 review and batch 8 editorial (AI-assisted), Oct 21, 2026
  items:
  - >-
    X5 and the comms loss-of-signal branch now open with "Only the robot pauses; crew care never waits
    for the link or the robot." (batch 7 review suggestion 29). Editorial; robot behaviour unchanged.
- date: '2026-10-21'
  version: '0.6'
  source: Batch 9 editorial (AI-assisted), Oct 21, 2026
  items:
  - Rashes are routed to RMP-SKIN-004 (planned); RMP-SKIN-003 is now the wound photo log.
- date: '2026-10-21'
  version: '0.7'
  source: Batch 11 editorial (AI-assisted), Oct 21, 2026
  items:
  - >-
    Cross-links to the batch 11 drafts no longer say "(planned)" now that those protocols exist as v0.1
    drafts.